HomeAbout UsRight of Way
Safety & Regulatory Compliance • Statutory Guidelines

Power Line Right of Way

Mandatory safety distance requirements and statutory regulations designed to safeguard human lives, prevent electrocution hazards, and guarantee infrastructure maintenance corridors.

330 KV: 25.0m Buffer132 KV: 15.0m Buffer33/11 KV: 5.5m BufferZero Encroachment Mandate
Mandatory Distance Requirements

Statutory Setbacks for All Voltage Capacities

The Right of Way (RoW) distance is measured symmetrically from the centre of the transmission or distribution tower to either side. These corridors must remain 100% free of residential structures, shops, billboards, and storage dumps.

Building Under Power Lines Is Strictly Illegal

Encroachment violates federal safety laws and exposes residents to catastrophic electrical flashovers, high voltage arcing, and collapse hazards.

S/No
Capacity & Voltage Grade
Mandatory Setback
01
330 KV

Extra High Voltage Transmission

25.0 Metres

12.5m from centre line each side

02
132 KV

High Voltage Transmission

15.0 Metres

7.5m from centre line each side

03
33 KV / 11 KV

Primary Distribution Network

5.5 Metres

2.75m from centre line each side

Regulatory Provisions

Core Provisions of Right of Way

Critical compliance points governing utility corridors for property developers, communities, and stakeholders

Statutory Rights

Land Acquisition & Easements

Electricity distribution and transmission utilities acquire legal easements to establish and safely maintain high-voltage lines, sub-stations, and associated grid hardware.

Statutory Requirement
Formal Governance

Legal & Regulatory Agreements

Formal legal agreements and environmental easements are established between Kaduna Electric, landowners, state governments, and urban planning authorities.

Statutory Requirement
Hazard Prevention

Electrocution & Safety Buffer

Right of Way creates a vital buffer zone to protect communities against flashovers, line collapses, accidental arcing, and unauthorized structural encroachments.

Statutory Requirement
Grid Reliability

24/7 Maintenance Access

Unobstructed corridors ensure emergency response and engineering crews can promptly access power lines for fault clearance, inspections, and vegetation management.

Statutory Requirement
Public Advocacy

Community Safety Awareness

Continuous public education across Kaduna, Sokoto, Kebbi, and Zamfara discouraging trading, farming, or residential building directly beneath energized conductors.

Statutory Requirement
Ecosystem Care

Environmental Considerations

Strict adherence to Nigerian environmental standards, minimizing ecosystem disruption while maintaining mandatory tree clearance and line vegetation control.

Statutory Requirement
Advisory Notice

Encroachment Reporting & Area Enquiries

Before purchasing land, commencing building projects, or erecting structures near utility lines, please consult your nearest Kaduna Electric Area Office or the QHSE department to verify legal right of way clearance.